AT77C104B
5347B–BIOM–08/04
Status Register Register Name:Status (8 bits)
Access Type:Read Only
Function:State of AT77C104B
CLICK: click detection
0: default
1: click detected
MOV: movement detection
0: default
1: X or Y movement detected
TRANSIT: not used, for testing only
SLICE: not used, for testing only
READERR: read error detection
0: default, no error
1: read error detected
Note: To clear the interrupts, the status register is initialized after each reading from the host.
b7 b6 b5 b4 b3 b2 b1 b0
CLICK MOV TRANSIT SLICE READERR
00000000