Rainbow-electronics ATtiny861_V Manuale Utente Pagina 125

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 236
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 124
125
2588B–AVR–11/06
ATtiny261/461/861
Bits 7:4- DT1H3:DT1H0: Dead Time Value for OC1x Output
The dead time value for the OC1x output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.
Bits 3:0- DT1L3:DT1L0: Dead Time Value for OC1x
Output
The dead time value for the OC1x
output. The dead time delay is set as a number of the pres-
caled timer/counter clocks. The minimum dead time is zero and the maximum dead time is the
prescaled time/counter clock period multiplied by 15.