3.0 Application Hints (Continued)
4.0 Typical Applications
DS100136-15
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn’t read, the outputs would go low and stay that way until the LM77 is read.
FIGURE 7. Temperature Response Diagram for ACPI Implementation
DS100136-16
FIGURE 8. Typical Application
LM77
www.national.com 14