Rainbow-electronics FARGO MAESTRO 100 (with TCP_IP) Manuale Utente Pagina 145

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 787
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 144
Serial Port Commands
DTE-DCE Character Framing +ICF
©Restricted
Page: 139 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 1 August 23, 2007
8.3.3 Parameters and Defined Values
<format>: character framing format
1 8 data 2 stop
<parity> parameter is ignored.
2 8 data 1 parity 1 stop
if no <parity> provided, 3 is used by default as <parity> value
.
3 8 data 1 stop
<parity> parameter is ignored.
default value
4 7 data 2 stop
<parity> parameter is ignored.
5 7 data 1 parity 1 stop
if no <parity> provided, 3 is used by default as <parity> value.
6 7 data 1 stop
<parity> parameter is ignored
.
<parity>: character framing parity
0 odd
1 even
2 mark
3 space
4 none (default value)
8.3.4 Parameter Storage
The <format> and <parity> parameters are stored in EEPROM using AT&W
command. The default value can be restored using AT&F.
Vedere la pagina 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 786 787

Commenti su questo manuale

Nessun commento